LPG CNG Reducer Regulator Vaporizer Kit 13mm Hole 12v Solenoid Coil

  • 1
  • 2

Brand Name : Brando

Model Number : BB13336518

Certification : CE

Place of Origin : China

MOQ : 1 set

Price : negotiation

Payment Terms : L/C, T/T, Western Union,Paypal, MoneyGram

Supply Ability : 500000 set per month

Delivery Time : 4-8 days

Packaging Details : Inner Box, Carton, Pallet

Type : Reducer Solenoid Coil

Material : BMC, Brass

Product name : LPG Pressure Reducer Solenoid Coil

Voltage : DC12V (Other can be customized)

Hole size : 13 mm

Power : DC: 17W

Color : Black (Other color can be customized)

Application : RGJ/RME MVAT3579/MVAT3755 Lovato/Tomasetto Type LPG Autogas Reducer Repair Kit

Insulation class : H

Connection type : DEUTCH

Contact Now

LPG CNG Reducer Regulator Vaporizer Kit 13mm Hole Electric Coil

The solenoid valve of the car includes a solenoid valve coil, which occupies this important position in the entire device, and the coil device as a whole cannot work. The development of automotive solenoid valves is relatively late, the main reason is the problem of coils. People have applied electromagnetic properties earlier, but when they started to study the coils suitable for solenoid valves, they could not find a suitable coil to carry out the work of energization.

All the coils for LPG multi valves and CNG reducers are available in several configurations, depending on the specific customer request.
The customization of dimensional and functional electrical parameters grants to the final customer high freedom on the technical aspect.
All the material used are able to withstand the strictest tests requested from the automotive sector.
This kind of coils may be used also in other applications, such as pneumatic and hydraulic sector

Technical parameter of Lovato Type LPG Reducer Solenoid Valve Coils:

Model number BB13336518
Normal voltage DC12V (Other can be customized)
Normal power DC:17W
Insulation class H
Connection type DEUTCH
Application

RGJ/RME LovatoType LPG Reducer Repair Kit

MVAT3579/MVAT3755 Tomasetto Lpg Reducer Accessories

Weight 122.5 g
Hole size 13 mm
Height 36.5 mm
Width 32 mm

Temperature rise and maximum temperature requirements of solenoid coil:

Insulation class Maximum normal temperature rise (℃) Maximum temperature(℃)
B 90 130
F 115 155
H 140 180
N 160 200
R 180 220
Tips: Not applicable to pulsating operating coils!

Main dimension of RGJ/RME Autogas Reducer Repair Kit Electric Magnetic Coils:

LPG CNG Reducer Regulator Vaporizer Kit 13mm Hole 12v Solenoid Coil

Physical map of LPG MVAT3579/MVAT3755 Tomasetto reducer electromagnetic coils:

LPG CNG Reducer Regulator Vaporizer Kit 13mm Hole 12v Solenoid CoilLPG CNG Reducer Regulator Vaporizer Kit 13mm Hole 12v Solenoid Coil

Application of DC12V LPG Autogas Reducer Conversion Kit Solenoid Coil:

LPG CNG Reducer Regulator Vaporizer Kit 13mm Hole 12v Solenoid CoilLPG CNG Reducer Regulator Vaporizer Kit 13mm Hole 12v Solenoid Coil

More details about Lovato type RGJ / RME reducer solenoid coils can be found below the Youtube video:

Notes on the use of solenoid valve coil:
1. When the coil is energized, it is strictly forbidden to cover to prevent overheating and burning;


2, electromagnetic coil, socket, electromagnet and connecting parts, it is strictly prohibited to hit the collision to avoid damage;


3. When the coil is energized for normal operation, due to its own heat, the temperature is high, please do not touch it;


4. The working pressure, temperature and viscosity of the medium shall not exceed the specified range;


5. The actual power supply voltage must not exceed the specified range;


6. Ordinary solenoid valve coils should not be used in explosive places;


7. The internal parts of the solenoid valve and the filtering device must be cleaned regularly;


8. Check the model and parameters on the valve label, which must meet the technical requirements of the site;


9. Check the coil, electromagnet and electrical socket to ensure no external damage;


10. When the solenoid valve coil is not used for a while, it can be stored in the room where 0 °C - 40 °C, relative humidity <80%, and no corrosive gas, no open storage is allowed;


11. When the electromagnetic valve is installed in the open air, a protective cover must be installed to ensure performance and extend the service life;


12, AC solenoid valve coils must not be energized with no load, otherwise there is a danger of burning;


13. The best installation method of the solenoid valve is perpendicular to the horizontal pipe, the coil is upward, and the maximum inclination angle is <30° during installation. Otherwise, normal use cannot be guaranteed;


14. Clean and purify the pipeline. The working medium of the solenoid valve should be clean. If the medium contains particulate impurities, a filter device must be installed on the pipeline before the valve;


15. Connect the valve's interface to the pipe according to the direction indicated by the arrow on the valve body, and ensure that the joint is well sealed.

Welcome to your inqiuiry!


Product Tags:

LPG CNG 12v solenoid coil

      

Regulator Vaporizer 12v solenoid coil

      

Tomasetto Type 12v solenoid coil

      
Best LPG CNG Reducer Regulator Vaporizer Kit 13mm Hole 12v Solenoid Coil wholesale

LPG CNG Reducer Regulator Vaporizer Kit 13mm Hole 12v Solenoid Coil Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Brando Hardware Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)